Autors: Deneva, M. A., Todorova, T, P., Nenchev, N, M.
Title: QUANTUM ELECTRONICS DEVICE FOR LASER-INTRACAVITY REGISTRATION OF POLLUTANTS WITH INCREASED SENSITIVITY
Keywords: quantum electronic device, laser intracavity spectroscopy

Abstract: We propose and show (theory, experimental test) (he feasibility of a new system for increasing of the intracavity-laser-spectroscopy (ILAS) sensibility for the specific case of the small number round-trips of the light in the laser, during the registration. In our proposal the non-favorable effect for ILAS of a re-injection without absorption at the investigated line is eliminated. The volume with the sample under investigation can be very long and with a very small diameter. In two valuable in practice cases our method is very competitive with the traditional ILAS-registration: i) when

References

  1. Demtroder, W.,, 1995, Laser spectroscopy, 2nd ed., USA, Springer
  2. Meyer,H, Y.,Nenchev, N, M., 1982, On Intracavity Absorption and Self Frequency-Locking in Pulsed Dye Lasers, OPTICS COMMUNICATIONS, Volume 41, pp. 292-295
  3. Nenchev, M.,, 1984, Cavity Configuration in a Dye Laser for Dispersion on the Two Output Beams, OPTICS COMMUNICATIONS, Volume 50, pp. 36-40
  4. Nenchev,M., Patrikov,B,T.,Tzanev,I,V.,, 1990, Use of a resonator with a new configuration in a YAG:Nd laser, J. QUANTUM ELECTRON, Volume 20(10), pp. 1209- 1211
  5. Deneva, M.,, 1997, Improvement of the spectral purity of tunable lasers using a self-selection interferometer cavity: comparison with a conventional cavity, Proc. SPIE, Volume 30, pp. 171-176

Issue

ELECTRONICS’ 2005,21 – 23 September, vol. 2, pp. 217, 2005, Albania,

Вид: пленарен доклад в международен форум