Autors: Fotis, G., Vita, V., Milushev, G. S., Mladenov, V. M.
Title: After installation testing and fault detection during the operation of HV submarine power cables
Keywords: Engineering controlled terms Fault detection; Installation;

Abstract: This paper presents the required testing of submarine cables after installation and the available fault detection techniques during their operation. This comprehensive testing is carried out during and after the cable installation. Submarine cables are used for the interconnection of the Greek islands with the European power system and the offshore wind farms that are also going to operate in the next few years in the Aegean Sea. Given the high expense of submarine cables, their flawless construction before installing the cables and before energizing them is of high importance. Therefore, these crucial issues are described in the CIGRE recommendations and the IEC and IEEE Standards, and they are presented in this work.

References

    Issue

    BulEF, pp. 1-5, 2023, Bulgaria, IEEE, DOI 10.1109/BulEF59783.2023.10406267

    Цитирания (Citation/s):
    1. Wei, L., Jin, J., Deng, K. and Liu, H., 2024. “Insulator defect detection in transmission line based on an improved lightweight YOLOv5s algorithm,” Electric Power Systems Research, vol. 233, pp. 1-13, ISSN 03787796, DOI 10.1016/j.epsr.2024.110464 (Web of Science, Scopus, Google Scholar) SJR 1.029, IF 3.3 - 2024 - в издания, индексирани в Scopus или Web of Science
    2. Lyu, Y., Luo, Y., Jia, Z., Fu, S., Tang, Y., Wang, Q. and Zeng, Y., 2024. “Benefit evaluation of HVAC and HVDC for offshore wind power transmission system under the multidimensional index,” Electric Power Systems Research, vol. 237, pp. 1-12, ISSN 03787796, DOI 10.1016/j.epsr.2024.111018 (Web of Science, Scopus, Google Scholar) SJR 1.029, IF 3.3 - 2024 - в издания, индексирани в Scopus или Web of Science
    3. Tekin, M. and Solmaz, R., 2024. “Effects of cross-linked polyethylene (XLPE) conductors in medium voltage power grids and load analysis,” Electric Power Systems Research, vol. 236, pp. 1-9, ISSN 0378-7796, https://doi.org/10.1016/j.epsr.2024.110930 (Web of Science, Scopus, Google Scholar) SJR 1.029, IF 3.3 - 2024 - в издания, индексирани в Scopus или Web of Science
    4. Li, S., Wang, M., Zhou, Y., Su, Q., Guo, P. and Wu, T., 2024. “Transmission line insulator condition detection based on improved lightweight YOLOv8n algorithm,” https://doi.org/10.21203/rs.3.rs-4880334/v1, https://www.researchsquare.com/article/rs-4880334/v1, pp. 1-9, (Google Scholar) - 2024 - от чужди автори в чужди издания, неиндексирани в Scopus или Web of Science

    Вид: публикация в международен форум, публикация в реферирано издание, индексирана в Scopus