Autors: Hristov, K. H., Genovski Ivan.
Title: Model research of the energy efficiency of a cogeneration backpressure steam turbine installation
Keywords: backpressure steam turbine, energy efficiency

Abstract: In the contemporary district heating systems (DHS) heat energy for the customers is generated by cogeneration method, which leads to the saving of primary energy resources compared to the separate production method. The most widespread technology for combined production is based on steam turbine installations with adjustable steam extraction and backpressure steam turbine. In these technologies district heating water is heated to the required temperature either in district heaters in case of steam turbine with adjustable steam extractions or in boiler-condenser in case of backpressure steam turbine installations. The temperature of the district heat water at the inlet of the CHP installation depends on the mode of operation of the DHS. The heat load, distributed to consumers, is regulated at the heat source (CHP installation) by temperature and flow rate of the district heating water, mainly following the change in climatic factors.

References

    Issue

    25th Scientific Conference on Power Engineering and Power Machines (PEPM’2020), vol. 207, pp. 10, 2020, Bulgaria, doi.org/10.1051/e3sconf/202020702004

    Full text of the publication

    Вид: пленарен доклад в международен форум, публикация в реферирано издание