Autors: Pandelova, A. L., Stoyanov, N. S., Dzhudzhev, B. P.
Title: Determination of Limit of Detection in Electrochemical Biosensors
Keywords: LOD , electrochemical biosensor , calibration curve

Abstract: One of the important parameters determining the quality of an electrochemical biosensor is the limit of detection (LOD). A definition of this parameter is given by the International Union of Pure and Applied Chemistry (IUPAC). Different approaches are known for calculating the LOD in different types of biosensors, each of which comes with advantages, disadvantages and limitations. Three methods are mainly applied to determine LOD from experimental data from low concentration standard deviations, from a calibration curve, and from instrument resolution. The calibration curve method was used to determine the LOD in amperometric electrochemical biosensors. Experimental data from really developed electrochemical biosensors - plant-tissue and enzyme-based - were used to perform the calculations. The resulting values for sensitivity and LOD are b=2.97mM/mgO2/1, SLOD =0.206 mM for plant-tissue biosensor and b=3.1mM/mgO2/1, SLOD =0.176 mM for enzyme-based biosensor. The calibration curve met

References

    Issue

    International Scientific Conference on Computer Science (COMSCI), pp. 1-4, 2023, Bulgaria, DOI: 10.1109/COMSCI59259.2023

    Цитирания (Citation/s):
    1. Diakov D., Nikolova H., Simulation study of femoral-acetabular implants fatigue, 2025, International Scientific Symposium Metrology and Metrology Assurance Mma, issue 2025, DOI 10.1109/MMA67107.2025.11309832, eissn 25349325 - 2026 - в издания, индексирани в Scopus
    2. Diakov D., Nikolova H., Gerchev A., Fatigue testing of total hip joint implants, 2025, International Scientific Symposium Metrology and Metrology Assurance Mma, issue 2025, DOI 10.1109/MMA67107.2025.11311245, eissn 25349325 - 2026 - в издания, индексирани в Scopus
    3. Yin Z., Qu Y., Yang Y., Wang C., Zhang C., Meng X., Chen Y., Chen G., Li B., Zhang J., Niu S., Han Z., Ren L., Wearable Multimodal Detection System for Real-Time In Situ Analysis of Exhaled Breath Condensate, 2026, ACS Sensors, issue 4, vol. 11, pp. 3469-3481, DOI 10.1021/acssensors.6c00279, eissn 23793694 - 2026 - в издания, индексирани в Scopus
    4. Lavecchia di Tocco F., Carrasco I.L., Beshchasna N., Cannistraro S., Opitz J., Bizzarri A.R., Short PNA probes for enhanced miR-155 detection by bioFET, 2026, Biosensors and Bioelectronics X, issue 0, vol. 30, DOI 10.1016/j.biosx.2026.100790, eissn 25901370 - 2026 - в издания, индексирани в Scopus

    Вид: пленарен доклад в международен форум, индексирана в Scopus